Location of labels
General InformationKIBS Servicing Precautions
There are a number of important precautions that should
be followed servicing the KIBS.
This KIBS is designed to be used with a 12 V sealed battery
as its power source. Do not use any other battery
except for a 12 V sealed battery as a power source.
Do not reverse the battery cable connec ...
Check 3-6: Neutral Indicator Light (LED) Inspection
Connect the leads in the same circuit as Check 3-2.
Connect the terminal [8] to the battery (–) terminal.
Check that the neutral indicator light (LED) [A] goes on.
If the indicator light does not go on, replace the meter unit.
...
Check 3-1: CAN Communication Line Resistance Inspection
Set the hand tester [A] to the ×1 Ω range and connect it
to the terminal [11] and [12] in the meter unit.
Special Tool - Hand Tester: 57001-1394
CAN Communication Line Resistance (at Meter Unit)
Standard: 122 126 Ω
If the tester reading is not specified, replace the meter ...