Hub Bearing Inspection
Exploded ViewCable, Wire, and Hose Routing
1. Clamp (Hold the regulator/rectifier lead. Run the lead inside of the
installation hole.)
2. Clamp (Bend down the clamp, and hold the main harness and the vacuum hose
(equipped
models).)
3. Clamp (Hold the air intake solenoid valve lead (equipped models).)
4. Run the vacuum hose under ...
Fuel Injector Fuel Line Inspection
Remove:
Fuel Tank (see Fuel Tank Removal)
Air Cleaner Housing (see Air Cleaner Housing Removal)
Disconnect:
Primary and Secondary Fuel Hoses (see Fuel Hose Replacement
in the Periodic Maintenance chapter)
Do not remove the nozzle assy from the air cleaner housing.
Be sure to pla ...
Transmission Assy Installation
Assemble the transmission assy (see Transmission Assy
Assembly).
Be sure that the dowel pins are in position.
Install the transmission assy on the crankcase.
Tighten:
Torque - Transmission Case Bolts: 20 N·m (2.0 kgf·m, 15
ft·lb)
Install:
Shift Shaft (see External Shift Mechani ...