Hub Bearing Inspection
Exploded ViewLiquid Gasket, Non-permanent Locking Agent
For applications that require Liquid Gasket or a
Non-permanent Locking Agent, clean the surfaces so
that no oil residue remains before applying liquid gasket or
non-permanent locking agent. Do not apply them excessively.
Excessive application can clog oil passages and
cause serious damage.
...
Camshaft Chain Tensioner Installation
Replace the O-ring [A] with a new one.
Apply grease to the new O-ring.
Release the stopper [B] and push the push rod [C] into the
interior of the tensioner body [D] so that the position of the
push rod is 3 or 4 notches [E] as shown in the figure.
Install the tensioner body so that the ...
Thermostat Inspection
Remove the thermostat (see Thermostat Removal).
Inspect the thermostat valve [A] at room temperature.
If the valve is open, replace the thermostat with a new
one.
To check valve opening temperature, suspend the thermostat
[A] in a container of water and raise the temperature
of ...