Refreshing Charge
Alternator Cover RemovalSpecifications
Whenever you see the symbols
shown below, heed their instructions!
Always follow safe operating and maintenance
practices.
DANGER
DANGER indicates a hazardous
situation which, if not avoided,
will result in death or serious injury.
WARNINGWARNING indicates a hazardous
situation whi ...
Crankshaft Sensor Peak Voltage Inspection
NOTE
Be sure the battery is fully charged.
Using the peak voltage adapter [A] is more reliable way
to determine the condition of the crankshaft sensor than
crankshaft sensor internal resistance measurements.
Disconnect the crankshaft sensor lead connector (see
Crankshaft Sensor ...
Check 3-1: CAN Communication Line Resistance Inspection
Set the hand tester [A] to the ×1 Ω range and connect it
to the terminal [11] and [12] in the meter unit.
Special Tool - Hand Tester: 57001-1394
CAN Communication Line Resistance (at Meter Unit)
Standard: 122 126 Ω
If the tester reading is not specified, replace the meter ...