Oil Pan Installation
Oil Pressure Relief Valve RemovalCheck 3-1: CAN Communication Line Resistance Inspection
Set the hand tester [A] to the ×1 Ω range and connect it
to the terminal [11] and [12] in the meter unit.
Special Tool - Hand Tester: 57001-1394
CAN Communication Line Resistance (at Meter Unit)
Standard: 122 126 Ω
If the tester reading is not specified, replace the meter ...
Exhaust Butterfly Valve Cable Installation
Confirm whether pulley [A] is an angle shown in the figure.
41.7° ±7° [B]
This position is original position of the pulley.
NOTE
Correct the position electrically after confirming the use
is discontinued and there is no damage when differing
from the angle of shown in the figure.
...
Exploded View
5. Other than US, CA, and CAL Models
6. The big diameter side of the dampers faces upward.
G: Apply grease.
L: Apply a non-permanent locking agent.
R: Replacement Parts
S: Follow the specified tightening sequence.
SS: Apply silicone sealant.
11. Immobilizer Ampli ...