Fuel Pressure InspectionStator Coil Installation
Apply a non-permanent locking agent to the threads of
the stator coil bolts and tighten them.
Torque - Stator Coil Bolts: 12 N·m (1.2 kgf·m, 106 in·lb)
Using a high flash-point solvent, clean off any oil or dirt
that may be on the silicone sealant coating area. Dry
them with a clea ...
Troubleshooting guide
Engine Does Not Start
Starter Motor Won’t Turn
Engine stop switch off
Transmission not in neutral
Fuse blown
Battery leads do not make good electrical
contact with battery terminals
Battery discharged
Engine Cranks, But Won’t Start
No fuel in tank
Fuel line clogged
Fuel ...
Commutator Cleaning and Inspection
Clean the metallic debris off the between commutator
segments [A].
NOTE
Do not use emery or sand paper on the commutator.
Check the commutator for damage or abnormal wear.
Replace the starter motor with a new one if there is any
damage or wear.
Visually inspect the commutato ...