ECU Communication Error (Service Code 39)
Fuel Pump Relay Removal/InstallationLiquid Gasket, Non-permanent Locking Agent
For applications that require Liquid Gasket or a
Non-permanent Locking Agent, clean the surfaces so
that no oil residue remains before applying liquid gasket or
non-permanent locking agent. Do not apply them excessively.
Excessive application can clog oil passages and
cause serious damage.
...
Torque Limiter Removal
Remove:
Starter Motor (see Starter Motor Removal in the Electrical
System chapter)
Throttle Body Assy Holder [A]
Breather Hose [B]
Roll up the heat insulation rubber plate [C].
Remove:
Torque Limiter Cover Bolts [A]
Torque Limiter Cover [B]
Remove:
Torque Limit ...
Valve-to-Guide Clearance Measurement (Wobble Method)
If a small bore gauge is not available, inspect the valve
guide wear by measuring the valve to valve guide clearance
with the wobble method as indicated below.
Insert a new valve [A] into the guide [B] and set a dial
gauge against the stem perpendicular to it as close as
possible to the cy ...