External Shift Mechanism Inspection
Exploded ViewRadiator Fan System
Fan Motor Inspection
Remove the air cleaner housing (see Air Cleaner Housing
Removal in the Fuel System (DFI) chapter).
Disconnect the connector [A].
Using an auxiliary leads, supply battery power to the fan
motor.
If the fan does not rotate, the fan motor is defective and
must be re ...
Backups
The ECU takes the following measures to prevent engine damage when the
DFI, ignition, S-KTRC
or immobilizer system parts have troubles.
Note:
(1): D-J Method: When the engine load is light like at idling or low
speed, the ECU determines the
injection quantity by calculating fr ...
Radiator Fan Relay Inspection
Refer to the Relay Circuit Inspection in the Electrical System
chapter
If the radiator fan relay is normal, check the wiring for
continuity, using the wiring diagram in this section.
Special Tool - Hand Tester: 57001-1394
If the wiring is good, check the ECU for its ground and
power supp ...