Air Line
Air Intake Duct InstallationOil Cooler Installation
Replace the O-ring [A] with a new one.
Apply grease to the new O-ring.
Install the water hoses and hose clamps [A] as shown in
the figure.
Water Hose (About 300 mm, 11.8 in.) [B]
Water Hose (About 130 mm, 5.1 in.) [C]
Yellow Paint [D]
Tighten:
Torque - Water Hose Clamp S ...
Exploded View
AL: Tighten the two clamp bolts alternately two times to ensure even
tightening torque.
G: Apply grease.
R: Replacement Parts
G: Apply grease.
L: Apply a non-permanent locking agent.
R: Replacement Parts
Specifications
...
Storage of Removed Parts
After all the parts including subassembly parts have been
cleaned, store the parts in a clean area. Put a clean cloth
or plastic sheet over the parts to protect from any foreign
materials that may collect before re-assembly.
Inspection
Reuse of worn or damaged parts may lead to serious acci ...